Polaris Scientific UVA-946HO Commercial High Output Ultraviolet Sterilization System
- High output germicidal lamps inactivate chlorineresistant parasites such as Cryptosporidium, Giardia, harmful bacteria like E.Coli, and viruses not visible to the naked eye.
- Specially designed, patented HO lamps provide consistent and reliable ultraviolet output over the entire life of the lamp (9000 hours) to ensure continuous purification.
- Durable stainless steel chamber to prolong life and eliminate ultraviolet light degradation.
- Controller display visually displays days of use and will alarm if lamp failure occurs.
- Simple to maintain and service allowing for easy lamp replacement.
- UV system controller features a sealed case to prevent damage from accidental water intrusion and is CSA and CE compliant.
Description:
Polaris Scientific Ultraviolet systems provide a sleek, compact design and economical ultraviolet water treatment for low flow and medium flow applications such as: light commercial reverse osmosis systems, water vending machines, food industry, laboratory, medical facility water, pharmaceutical, cosmetic processes, final electronic component rinsing and recirculation loops to name a few.
SAFE
- No need to handle toxic or corrosive chemicals or by-products
- Microbiologically free water without the use of potentially dangerous chemicals
- UV imparts no change in taste, odor, pH or conductivity
- No trihalomethanes (THM's) formation
SIMPLE
- Fast and simple installation with three connection (two water and one electrical).
- Maintenance involves annual lamp replacement (provided water quality parameters are met).
- Automatic unattended and user friendly operation.
EFFICIENT
- Compact units with 304 stainless steel reactor chamber, polished for laboratory and medical use, require minimum space.
- Microorganisms are inactivated within seconds; eliminates the need for long retention times or retention tanks.
- Counter / Timer
- Visual Warning - “Power-On" LED
- Audible Lamp Failure Alarm
- Lamp Replacement Alarm
ECONOMICAL
- No moving parts to wear out of break.
- Lower capital investment when compared to chlorine or ozone system.
E. Coli
Giardia
Viruses
Specifications
Part Number |
Flow Rate @ 95% UVT POLARIS STANDARD (30 MJ/CM2) |
Rated Life (hrs) |
Lamp Watts |
Voltage at 50/60HZ |
Visual Warning |
# of Lamps |
Port size I/O | Water Chamber |
Timer |
---|---|---|---|---|---|---|---|---|---|
UVA-418HO | 18 gpm (70 lpm) | 9,000 | 48W | 110V/220V | LED | 1 | 3/4" FNPT / 1" MNPT | STAINLESS 304 | |
UVA-630HO | 30 gpm (113 lpm) | 9,000 | 58W | 110V/220V | LED | 1 | 3/4" FNPT / 1" MNPT | STAINLESS 304 | |
UVA-946HO | 46 gpm (175 lpm) | 9,000 | 90W | 110V/220V | LED | 1 | 1.5" MNPT | STAINLESS 304 |
Maximum Concentration Levels | |
---|---|
Iron | < 0.3 ppm (0.3 mg/L) |
Hardness | < 7 gpg (120 mg/L) |
Turbidity | < 1 NTU |
Manganese | < 0.05 PPM (0.05 mg/L) |
Tannins | < 0.1 ppm (0.1 mg/L) |
UV Transmittance | > 75% |
Effectively treating water with higher concentration levels than listed above can be accomplished with WECO reverse osmosis, katalox light and/or cation softening upstream of UV. Chat with us to discuss options.
Note: UV should be the final piece of treatment equipment before the faucet.
Parts & Accessories | |||||||||
---|---|---|---|---|---|---|---|---|---|
Part Number |
Lamp | Quartz Sleeve |
Electronic Ballast |
Additional Accessories Specific to your UV System | |||||
UVA-418HO | GLHO48PP | QS48HO | HOB-4890 | UV-NUT-1 / UV-NUT-2 | UV-32 SPRING | UV-WASHER | UV-SEAL | UV-PLUG | CLP-35UV |
UVA-630HO | GLHO58PP | QS58HO | HOB-4890 | UV-NUT-1 / UV-NUT-2 | UV-32 SPRING | UV-WASHER | UV-SEAL | UV-PLUG | CLP-35UV |
UVA-946HO | GLHO90PP | QS90HO | HOB-4890 | UV-NUT-1 / UV-NUT-2 | UV-39 SPRING | UV-WASHER | UV-SEAL | UV-PLUG | CLP-35UV |
Product Rating
Warranty Information
- Limited 5-year warranty on stainless steel housing
- Limited 1-year warranty on electronics
Manufactured by
P.O. Box 2235
Chino Hills, CA 91709 USA